Features

Compact & Customized

  • Compact and economical civil work
  • Customized design for each customer

Reliability & Safety

  • Tested according to international standards
  • Metal partitions between each compartment to minimize damage to adjacent compartments
  • Internal arc resistant structure and pressure relief systems for personal safety
  • Circuit breaker drawing in/out with the door closed
  • Various optional accessories including interlocks and padlocks

Convenience

  • Applied maintenance-free VCB
  • Minimized maintenance and simplified inspection

Compact & Customized

  • Compact and economical civil work
  • Customized design for each customer

Reliability & Safety

  • Tested according to international standards
  • Metal partitions between each compartment to minimize damage to adjacent compartments
  • Internal arc resistant structure and pressure relief systems for personal safety
  • Circuit breaker drawing in/out with the door closed
  • Various optional accessories including interlocks and padlocks

Convenience

  • Applied maintenance-free VCB
  • Minimized maintenance and simplified inspection

Specification


Rating Specification
Model S7 S12 S17 S24 S36
Rated voltage (kV, rms) 7.2 12 17.5 24 36
Power frequency withstand
voltage (kV, rms)
20 28 38 50 70
Lightning impulse withstand
voltage (kV, peak)
60 75 95 125 170
Degree of protection IP4X IP4X IP4X IP4X IP4X IP4X
Short-time withstand current
(kA/s)
25/3 40/3 50/3 Same
with S7
model
25/3 40/3 50/3 25/3 40/3 25/3,
31.5/3,
40/3
Internal arc withstand current
(kA/s)
25/1 40/1 50/0.5 25/1 40/1 50/0.5 25/1 40/0.5 40/1
Rated current (A, rms) 630,
1250,
2000
1250,
2000,
3150,
4000
1250,
2000,
2500,
3150,
4000,
5000
630,
1250,
2000
1250,
2000,
3150,
4000
1250,
2000,
2500,
3150,
4000
630,
1250,
2000,
2500
1250,
2000,
3150
1250,
2000,
3150

Rating Specification
Model S7 S12 S17 S24 S36
Rated voltage (kV, rms) 7.2 12 17.5 24 36
Power frequency withstand
voltage (kV, rms)
20 28 38 50 70
Lightning impulse withstand
voltage (kV, peak)
60 75 95 125 170
Degree of protection IP4X IP4X IP4X IP4X IP4X IP4X
Short-time withstand current
(kA/s)
25/3 40/3 50/3 Same
with S7
model
25/3 40/3 50/3 25/3 40/3 25/3,
31.5/3,
40/3
Internal arc withstand current
(kA/s)
25/1 40/1 50/0.5 25/1 40/1 50/0.5 25/1 40/0.5 40/1
Rated current (A, rms) 630,
1250,
2000
1250,
2000,
3150,
4000
1250,
2000,
2500,
3150,
4000,
5000
630,
1250,
2000
1250,
2000,
3150,
4000
1250,
2000,
2500,
3150,
4000
630,
1250,
2000,
2500
1250,
2000,
3150
1250,
2000,
3150