DAIS
Home
Smart Power Solution
Power Distribution
MV SWGR
Benefits
Uncompromised Operator Safety
- Internal arc classification AFLR 1s complies with IEC standards
- Logical mechanical and electrical interlocks to prevent improper operation
- Application of arc duct to protect the entire equipment
- Monitors electric currents and operating conditions by an indicator
Top-Tier Level of Reliability
- The largest supply record in the domestic industrial plant market with more than 500 switchgear panels in operation
- M2, E2, and C2 endurance class of vacuum interrupters
- Performed by high-quality vacuum interrupters with permanent magnetic actuators
- Verified a wide range of tests in association with insulation performance
Minimum Operating Costs
- Compact top-entry design of the panels to minimize space
- Efficient maintenance with cable plug-in system
Uncompromised Operator Safety
- Internal arc classification AFLR 1s complies with IEC standards
- Logical mechanical and electrical interlocks to prevent improper operation
- Application of arc duct to protect the entire equipment
- Monitors electric currents and operating conditions by an indicator
Top-Tier Level of Reliability
- The largest supply record in the domestic industrial plant market with more than 500 switchgear panels in operation
- M2, E2, and C2 endurance class of vacuum interrupters
- Performed by high-quality vacuum interrupters with permanent magnetic actuators
- Verified a wide range of tests in association with insulation performance
Minimum Operating Costs
- Compact top-entry design of the panels to minimize space
- Efficient maintenance with cable plug-in system
Specification
Rating |
Specification |
Model |
GESG-0222-TC |
GESG-0220-TC |
Rated Voltage (kV, rms) |
25.8 |
25.8 |
Rated Breaking Current (kA, rms) |
25 |
25 |
Rated Nominal Current (A, rms) |
2000 |
630 |
Rated Frequency (Hz) |
60 |
60 |
Rated Duration of Short-circuit (s) |
1 |
1 |
Rated Peak Withstand Current (kA, Peak) |
65 |
65 |
Rated Power Frequency Withstand Voltage (kV, rms) |
60 |
60 |
Rated Lightning Impulse Withstand Voltage (kV, 1.2 X 50 ㎲) |
150 |
150 |
Degree of Protection (IP) |
4X |
4X |
IAC Classification |
IAC A FLR / 25 kA 1 s |
IAC A FLR / 25 kA 1 s |
Insulation Material |
Epoxy / FRP |
Epoxy / FRP |
Insulaton Medium |
Dry Air |
Dry Air |
Applicable Standards |
IEC 62271-100, 203 / ES 5925-0001, ES 6110-0002 / GS 5925-0128 |
IEC 62271-100, 203 / ES 5925-0001, ES 6110-0002 / GS 5925-0128 |
Rating |
Specification |
Model |
GESG-0222-TC |
GESG-0220-TC |
Rated Voltage (kV, rms) |
25.8 |
25.8 |
Rated Breaking Current (kA, rms) |
25 |
25 |
Rated Nominal Current (A, rms) |
2000 |
630 |
Rated Frequency (Hz) |
60 |
60 |
Rated Duration of Short-circuit (s) |
1 |
1 |
Rated Peak Withstand Current (kA, Peak) |
65 |
65 |
Rated Power Frequency Withstand Voltage (kV, rms) |
60 |
60 |
Rated Lightning Impulse Withstand Voltage (kV, 1.2 X 50 ㎲) |
150 |
150 |
Degree of Protection (IP) |
4X |
4X |
IAC Classification |
IAC A FLR / 25 kA 1 s |
IAC A FLR / 25 kA 1 s |
Insulation Material |
Epoxy / FRP |
Epoxy / FRP |
Insulaton Medium |
Dry Air |
Dry Air |
Applicable Standards |
IEC 62271-100, 203 / ES 5925-0001, ES 6110-0002 / GS 5925-0128 |
IEC 62271-100, 203 / ES 5925-0001, ES 6110-0002 / GS 5925-0128 |