Features
Measurement Function
- High precision measurement of various measurement elements (25 elements)
- Event recording (256 samples)
- Select Before Operating (SBO) function
Convenience Function
- Color touch graphic LCD, 20x4 Character LCD
- Various self-diagnosis functions (Power Fail)
Communication Function
- Various communication functions
- Ethernet RSTP (Rapid Spanning Tree Protocol)
Measurement Function
- High precision measurement of various measurement elements (25 elements)
- Event recording (256 samples)
- Select Before Operating (SBO) function
Convenience Function
- Color touch graphic LCD, 20x4 Character LCD
- Various self-diagnosis functions (Power Fail)
Communication Function
- Various communication functions
- Ethernet RSTP (Rapid Spanning Tree Protocol)
Measurement
| Model |
Measurement |
Display range |
Accuracy |
Remarks |
| GIMAC-II Plus |
Current, I |
0.000A ~ 999.99kA |
±0.3% |
Ia, Ib, Ic, In |
| Voltage, V |
0.000V ~ 999.99kV |
±0.3% |
Va, Vb, Vc, Vab, Vbc, Vca |
| Active power, Watts |
0.000W ~ 99999.9MW |
±0.5% |
+ : Forward - : Revers |
| Reactive power, Var |
0.000Var ~ 99999.9MVar |
±0.5% |
| Apparent power, VA |
0.000VA ~ 99999.9MVA |
±0.5% |
| Active energy, Wh |
0.000Wh ~ 99999.9MWh |
±0.5% |
| Reactive energy, Varh |
0.000Varh ~ 99999.9MVarh |
±0.5% |
|
| Frequency, F |
45 ~ 70Hz |
±0.05Hz |
|
| Power factor, PF |
-1.000 ~ 1.000 |
±0.5% |
cos θ (+ : Lag, - : Lead) |
| Phase |
0.000o~ 360.00o |
±0.5o |
|
| Normal current, I1 |
0.000A ~ 999.99kA |
|
|
| Reverse phase current, I2 |
0.000A ~ 999.99kA |
|
|
| Zero phase voltage, V。 |
0.000V ~ 999.99kV |
±0.5% |
V。, V。_max |
| Normal voltage, V1 |
0.000V ~ 999.99kV |
|
|
| Reverse phase voltage, V2 |
0.000V ~ 999.99kV |
|
|
| Unbalanced factor |
0.000 ~ 100.00% |
|
|
| Harmonics I |
0.000A ~ 999.99kA |
|
2nd ~15th |
| Harmonics V |
0.000V ~ 999.99kV |
|
2nd ~15th |
| THD(V, I) |
|
|
|
| TDD(I) |
|
|
|
| k-Factor |
|
|
|
| Demand I |
0.000A ~ 999.99kA |
|
Peak demand |
| Demand W |
0.000W ~ 99999.9MW |
|
Peak demand |
| AI (Analog Input) |
DC 4.000 ~ 20.00mA |
±0.5% |
|
| Model |
Measurement |
Display range |
Accuracy |
Remarks |
| GIMAC-II Plus |
Current, I |
0.000A ~ 999.99kA |
±0.3% |
Ia, Ib, Ic, In |
| Voltage, V |
0.000V ~ 999.99kV |
±0.3% |
Va, Vb, Vc, Vab, Vbc, Vca |
| Active power, Watts |
0.000W ~ 99999.9MW |
±0.5% |
+ : Forward - : Revers |
| Reactive power, Var |
0.000Var ~ 99999.9MVar |
±0.5% |
| Apparent power, VA |
0.000VA ~ 99999.9MVA |
±0.5% |
| Active energy, Wh |
0.000Wh ~ 99999.9MWh |
±0.5% |
| Reactive energy, Varh |
0.000Varh ~ 99999.9MVarh |
±0.5% |
|
| Frequency, F |
45 ~ 70Hz |
±0.05Hz |
|
| Power factor, PF |
-1.000 ~ 1.000 |
±0.5% |
cos θ (+ : Lag, - : Lead) |
| Phase |
0.000o~ 360.00o |
±0.5o |
|
| Normal current, I1 |
0.000A ~ 999.99kA |
|
|
| Reverse phase current, I2 |
0.000A ~ 999.99kA |
|
|
| Zero phase voltage, V。 |
0.000V ~ 999.99kV |
±0.5% |
V。, V。_max |
| Normal voltage, V1 |
0.000V ~ 999.99kV |
|
|
| Reverse phase voltage, V2 |
0.000V ~ 999.99kV |
|
|
| Unbalanced factor |
0.000 ~ 100.00% |
|
|
| Harmonics I |
0.000A ~ 999.99kA |
|
2nd ~15th |
| Harmonics V |
0.000V ~ 999.99kV |
|
2nd ~15th |
| THD(V, I) |
|
|
|
| TDD(I) |
|
|
|
| k-Factor |
|
|
|
| Demand I |
0.000A ~ 999.99kA |
|
Peak demand |
| Demand W |
0.000W ~ 99999.9MW |
|
Peak demand |
| AI (Analog Input) |
DC 4.000 ~ 20.00mA |
±0.5% |
|
Specification
| Rating |
Specification |
| Wirings |
1P2W, 1P3W, 3P3W, 3P4W |
| Input |
Frequency |
50Hz/60Hz |
| Voltage |
PT |
10~230V (110V) |
| GPT |
2.2~230V |
| Current |
CT |
0.05~6A or 0.01~1.2 (1A) |
| Control voltage |
AC/DC 110V or AC/DC 220V |
| Power consumption |
Max. 30W |
| Burden |
PT |
Max. 1.0VA |
| CT |
Max. 1.0VA |
| Input contact 10EA |
Digital Input : AC/DC 110V or AC/DC 220V |
| Output contact |
2EA for power |
AC 250V 16A/DC 30V 16A 3840VA/480W |
| 8EA for alarm |
AC 250V 16A/DC 30V 16A 3840VA/480W |
| Insulation Resistance Over |
DC 500V 100㏁ |
| Insulation Voltage |
AC 2kV (1kV) / 1min |
| Impulse Voltage |
AC 5kV (3kV) / 1.2×50㎲ |
| Overload withstand |
Current circuit |
1.2 In for 3 hours 8 In for 2 seconds |
| Voltage circuit |
1.15 Vn for 3 hours |
| Fast Transient/Burst Immunity |
Power Input 4kV (PT, CT) Other Input 2kV (Analog Input 1kV) |
| ESD(Electrostatic Discharge) |
Air 8kV Contact 6kV |
| Operation temperature |
-10℃ ~ 55℃ |
| Storage temperature |
-25℃ ~ 70℃ |
| Humidity Average |
Within 80% RH, no condensation |
| Altitude |
2000m and below |
| Others |
Non-impact place Non-air pollution place |
| Standard |
IEC 60255, IEC 61000-4 |
| Communication |
Modbus/RS485, Ethernet IEC61850 MMS/Ethernet |
| Dimension(W×H×D) |
190×255×116 (mm) |
| Weight |
3.6 kg |
| Rating |
Specification |
| Wirings |
1P2W, 1P3W, 3P3W, 3P4W |
| Input |
Frequency |
50Hz/60Hz |
| Voltage |
PT |
10~230V (110V) |
| GPT |
2.2~230V |
| Current |
CT |
0.05~6A or 0.01~1.2 (1A) |
| Control voltage |
AC/DC 110V or AC/DC 220V |
| Power consumption |
Max. 30W |
| Burden |
PT |
Max. 1.0VA |
| CT |
Max. 1.0VA |
| Input contact 10EA |
Digital Input : AC/DC 110V or AC/DC 220V |
| Output contact |
2EA for power |
AC 250V 16A/DC 30V 16A 3840VA/480W |
| 8EA for alarm |
AC 250V 16A/DC 30V 16A 3840VA/480W |
| Insulation Resistance Over |
DC 500V 100㏁ |
| Insulation Voltage |
AC 2kV (1kV) / 1min |
| Impulse Voltage |
AC 5kV (3kV) / 1.2×50㎲ |
| Overload withstand |
Current circuit |
1.2 In for 3 hours 8 In for 2 seconds |
| Voltage circuit |
1.15 Vn for 3 hours |
| Fast Transient/Burst Immunity |
Power Input 4kV (PT, CT) Other Input 2kV (Analog Input 1kV) |
| ESD(Electrostatic Discharge) |
Air 8kV Contact 6kV |
| Operation temperature |
-10℃ ~ 55℃ |
| Storage temperature |
-25℃ ~ 70℃ |
| Humidity Average |
Within 80% RH, no condensation |
| Altitude |
2000m and below |
| Others |
Non-impact place Non-air pollution place |
| Standard |
IEC 60255, IEC 61000-4 |
| Communication |
Modbus/RS485, Ethernet IEC61850 MMS/Ethernet |
| Dimension(W×H×D) |
190×255×116 (mm) |
| Weight |
3.6 kg |