Features

  • Provide various Ethernet, serial network solutions
  • Large capacity data & high-speed network system
  • Easy protocol editing and network parameter setting: XG5000
  • High reliability: Ring system(RAPIEnet)
  • Various diagnostic functions and network status information
  • Provide various Ethernet, serial network solutions
  • Large capacity data & high-speed network system
  • Easy protocol editing and network parameter setting: XG5000
  • High reliability: Ring system(RAPIEnet)
  • Various diagnostic functions and network status information

Ethernet

XGT Ethernet system (XGL-EFMTB, XGL-EFMFB)

Features

  • Supports max media speed of 1Gbps
  • Supports 1Ch 2Ports
    • Line topology configuration with relay parameter setting
    • Dual ports (T.Pair / F.Optic)
  • Server standard maximum communication load 5,000pps
  • Fiber optic module (XGL-EFMTB) has replaceable connector, communication speed is improved to 1Gbps, and maintenance is easy
  • XG5000 old and new versions available
  • User defined frame UI enhancements make it easier to use
  • Various diagnostics made possible by strengthening log function
  • Open ethernet and dedicated protocol (RAPIEnet)


Specifications

- Open Ethernet
Item Product Name
XGL-EFMTB XGL-EFMFB
Transmission Specification Baud rate 10/100/1000Mbps 100/1000Mbps
Transmission Type Base Band
Max. extended length between nodes 100m(Node-Hub) 2km
Max. segment length - -
Max. number of nodes Hub connection(Up to 9 recommended) 30/Segments
Distance between nodes - Integral times of 0.5m
Max. protocol size 1,500 Byte
Access method to service zone CSMA/CD
Frame error check CRC 16 = X15+X14+X13+....+X2+X+1
Basic Specification Current consumption (5V) 100Mbps 560mA 750mA
1Gbps 900mA 740mA
Weight 146 g 156 g -

Formerica SFP standard

XGT Ethernet system (XGL-EFMTB, XGL-EFMFB)

Features

  • Supports max media speed of 1Gbps
  • Supports 1Ch 2Ports
    • Line topology configuration with relay parameter setting
    • Dual ports (T.Pair / F.Optic)
  • Server standard maximum communication load 5,000pps
  • Fiber optic module (XGL-EFMTB) has replaceable connector, communication speed is improved to 1Gbps, and maintenance is easy
  • XG5000 old and new versions available
  • User defined frame UI enhancements make it easier to use
  • Various diagnostics made possible by strengthening log function
  • Open ethernet and dedicated protocol (RAPIEnet)


Specifications

- Open Ethernet
Item Product Name
XGL-EFMTB XGL-EFMFB
Transmission Specification Baud rate 10/100/1000Mbps 100/1000Mbps
Transmission Type Base Band
Max. extended length between nodes 100m(Node-Hub) 2km
Max. segment length - -
Max. number of nodes Hub connection(Up to 9 recommended) 30/Segments
Distance between nodes - Integral times of 0.5m
Max. protocol size 1,500 Byte
Access method to service zone CSMA/CD
Frame error check CRC 16 = X15+X14+X13+....+X2+X+1
Basic Specification Current consumption (5V) 100Mbps 560mA 750mA
1Gbps 900mA 740mA
Weight 146 g 156 g -

Formerica SFP standard

Computer-Link

XGT Computer-Link (XGL-C22B, XGL-CH2B, XGL-C42B)

Features

  • Smart server recognizes the protocol (XGT dedicated communication or Modbus RTU/ASCII) automatically and activates
  • Repeater mode may be used use as an insulated repeater or convert RS-232C to RS422/485
  • Contains a built- in termination resistor and can be set in the basic parameter window
  • Easy protocol editing and communication parameter setting: XG5000
  • Long-distance communication via modem connection
  • Dedicated protocol for multi-drop configuration connectable up to 32 units
  • Flexible communication speed setting (300~115,200bps)
  • Supports full duplex and half duplex communication
  • Max. 12 modules available in one CPU
  • Various connection to MMI S/W (XGT, Modbus RTU, Modbus ASCII)
  • Various diagnosis functions using XG5000 (I/O, link status, service status)
  • Supports simultaneously dedicated service in remote connection

Specifications

Item Specification
XGL-C22B XGL-CH2B XGL-C42B
Serial communicat-ion channel RS-232C 2 channels 1 channel -
Conforms to RS-232C standard
Line config 1:1
RS-422/485 - 1 channel 2 channels
Conforms to RS-422/485 standards
Line config 1:1, 1:n, n:1
Modem connection function Remote communication with external devices is available via public telephone line by connecting external modem to the module. -
Operating mode
(specified per port)
P2P XGT client, Modbus ASCII/RTU client, Use defined communication
SERVER XGT server, Modbus ASCII/RTU server
Data type Start Bit 1
Data Bit 7 or 8
Stop Bit 1 or 2
Parity Even/Odd/None
Synchronization type Asynchronous type
Detecting error BYTE SUM, WORD SUM, BYTE XOR, DLE AB, DLE SIEMENS, LSIS CRC, CRC 16, BYTE SUM 2’ COMP, BYTE SUM 1’s COMP 7BIT SUM, 7BIT XOR, CRC 16 IBM, CRC 16 CCITT
Transmission speed (bps) 300 / 600 / 1,200 / 1,800 / 2,400 / 3,600 / 4,800 / 7,200 / 9,600/19,200 / 38,400 / 57,600 / 64,000 / 76,800 / 115,200bps
Station No. setting Setting range : 0-31, Max. station No. : 32 stations
Transmission Distance(m) RS-232C: Max.15 (extendible if modem used) -
- RS-422/485: Max. 1,200m
Diagnosis function Status LED diagnosis XG5000 diagnosis service(Frame monitor, Status by service, Loop-Back diagnosis) History, Saving history
Appearance size(mm) 98(H) X 27(W) X 90(D)
Current consumption(mA) 420 480 520
Weight(g) 121 119 116

XGT Computer-Link (XGL-C22B, XGL-CH2B, XGL-C42B)

Features

  • Smart server recognizes the protocol (XGT dedicated communication or Modbus RTU/ASCII) automatically and activates
  • Repeater mode may be used use as an insulated repeater or convert RS-232C to RS422/485
  • Contains a built- in termination resistor and can be set in the basic parameter window
  • Easy protocol editing and communication parameter setting: XG5000
  • Long-distance communication via modem connection
  • Dedicated protocol for multi-drop configuration connectable up to 32 units
  • Flexible communication speed setting (300~115,200bps)
  • Supports full duplex and half duplex communication
  • Max. 12 modules available in one CPU
  • Various connection to MMI S/W (XGT, Modbus RTU, Modbus ASCII)
  • Various diagnosis functions using XG5000 (I/O, link status, service status)
  • Supports simultaneously dedicated service in remote connection

Specifications

Item Specification
XGL-C22B XGL-CH2B XGL-C42B
Serial communicat-ion channel RS-232C 2 channels 1 channel -
Conforms to RS-232C standard
Line config 1:1
RS-422/485 - 1 channel 2 channels
Conforms to RS-422/485 standards
Line config 1:1, 1:n, n:1
Modem connection function Remote communication with external devices is available via public telephone line by connecting external modem to the module. -
Operating mode
(specified per port)
P2P XGT client, Modbus ASCII/RTU client, Use defined communication
SERVER XGT server, Modbus ASCII/RTU server
Data type Start Bit 1
Data Bit 7 or 8
Stop Bit 1 or 2
Parity Even/Odd/None
Synchronization type Asynchronous type
Detecting error BYTE SUM, WORD SUM, BYTE XOR, DLE AB, DLE SIEMENS, LSIS CRC, CRC 16, BYTE SUM 2’ COMP, BYTE SUM 1’s COMP 7BIT SUM, 7BIT XOR, CRC 16 IBM, CRC 16 CCITT
Transmission speed (bps) 300 / 600 / 1,200 / 1,800 / 2,400 / 3,600 / 4,800 / 7,200 / 9,600/19,200 / 38,400 / 57,600 / 64,000 / 76,800 / 115,200bps
Station No. setting Setting range : 0-31, Max. station No. : 32 stations
Transmission Distance(m) RS-232C: Max.15 (extendible if modem used) -
- RS-422/485: Max. 1,200m
Diagnosis function Status LED diagnosis XG5000 diagnosis service(Frame monitor, Status by service, Loop-Back diagnosis) History, Saving history
Appearance size(mm) 98(H) X 27(W) X 90(D)
Current consumption(mA) 420 480 520
Weight(g) 121 119 116

DeviceNet

XGT DeviceNet system (XGL-DMEB)

Features

  • DeviceNet protocol
  • Direct control of various I/O devices via Dnet system
  • Max. 63 slave modules controlled by one master module
  • Flexibility in network configuration: Multi-drop and T branch connection
  • Connectable to other master module and various slave modules
  • Provides an ‘ Auto Network Scan’ function and various information with configuration tools (N Configurator)
  • Communicates a high-speed link parameter
  • Connectable to various slave I/O including other module
    (Common I/O, Actuator, Switch, Optical switch, Valve, Inverter, A/D module, Position controller etc..)
  • Automatic monitoring of slave modules in the network: Auto-scan (XG5000)
  • Easy expansion: Up to 12 master modules
  • Network setting by N Configurator/XG5000 (Parameter setting, diagnosis and monitoring)

Specifications

Item Performance Specifications
Transmission
Specification
Transmission Speed (kbps) 125/250/500
Transmission Type I/O Connection G2, UCMM
I/O Communication Poll, Bit strobe, COS, Cyclic
Communication distance(m) Thick Cable 500 (125kbps)/250 (250kbps)/100 (500kbps)
Thin Cable 100 (125/250/500kbps)
Terminal resistance (W) 121 (1%, 1/4W)
Max.drop length(m) 125 kbps 6 (Max. extended length 156)
250 kbps 6 (Max. extended length 78)
500 kbps 6 (Max. extended length 39)
Data Packet 0~8 Bytes
Message Access Control CSMA/NBA
Network Structure Trunk/drop line
Power/Signal cable inside the identical network cable
Bus Type Poll type
Max. number of nods Up to 64 (including master) MAC IDs (MAC Identifier)
System Features Insertion and removal of nod available in voltage On status
Operation Voltage DC 24V
Diagnosis Function Module: Checks duplicated station/ Checks CRC error
N Configurator: Detects defective station/Checks BusOff/Auto-scan function XG5000: Monitors High-speed link
Master/Slave Operation Available only in master
Parameter setting 1) N Configurator (CONFIG Port of Dnet I/F)
2) Setting to High-speed link of XG5000 (RS-232C of CPU module or USB port)
XG5000
(High -speed link)
Data process unit Byte
Send/Receive period Select among 20ms, 50ms, 100ms, 200ms, 500ms, 1s, 5s and 10s - Default : 20ms
Max. communication point Send 128,520points, Receive 128,520 points, 16,065 bytes respectively
Max. block number 63 (Setting range: 0~62)
Max. point number per block 2040 points (255 bytes)
Basic Specification Max. modules installed Up to 12 (available on basic base and added base)
Internal-consumed current (mA) 350mA
Weight (g) 81g

XGT DeviceNet system (XGL-DMEB)

Features

  • DeviceNet protocol
  • Direct control of various I/O devices via Dnet system
  • Max. 63 slave modules controlled by one master module
  • Flexibility in network configuration: Multi-drop and T branch connection
  • Connectable to other master module and various slave modules
  • Provides an ‘ Auto Network Scan’ function and various information with configuration tools (N Configurator)
  • Communicates a high-speed link parameter
  • Connectable to various slave I/O including other module
    (Common I/O, Actuator, Switch, Optical switch, Valve, Inverter, A/D module, Position controller etc..)
  • Automatic monitoring of slave modules in the network: Auto-scan (XG5000)
  • Easy expansion: Up to 12 master modules
  • Network setting by N Configurator/XG5000 (Parameter setting, diagnosis and monitoring)

Specifications

Item Performance Specifications
Transmission
Specification
Transmission Speed (kbps) 125/250/500
Transmission Type I/O Connection G2, UCMM
I/O Communication Poll, Bit strobe, COS, Cyclic
Communication distance(m) Thick Cable 500 (125kbps)/250 (250kbps)/100 (500kbps)
Thin Cable 100 (125/250/500kbps)
Terminal resistance (W) 121 (1%, 1/4W)
Max.drop length(m) 125 kbps 6 (Max. extended length 156)
250 kbps 6 (Max. extended length 78)
500 kbps 6 (Max. extended length 39)
Data Packet 0~8 Bytes
Message Access Control CSMA/NBA
Network Structure Trunk/drop line
Power/Signal cable inside the identical network cable
Bus Type Poll type
Max. number of nods Up to 64 (including master) MAC IDs (MAC Identifier)
System Features Insertion and removal of nod available in voltage On status
Operation Voltage DC 24V
Diagnosis Function Module: Checks duplicated station/ Checks CRC error
N Configurator: Detects defective station/Checks BusOff/Auto-scan function XG5000: Monitors High-speed link
Master/Slave Operation Available only in master
Parameter setting 1) N Configurator (CONFIG Port of Dnet I/F)
2) Setting to High-speed link of XG5000 (RS-232C of CPU module or USB port)
XG5000
(High -speed link)
Data process unit Byte
Send/Receive period Select among 20ms, 50ms, 100ms, 200ms, 500ms, 1s, 5s and 10s - Default : 20ms
Max. communication point Send 128,520points, Receive 128,520 points, 16,065 bytes respectively
Max. block number 63 (Setting range: 0~62)
Max. point number per block 2040 points (255 bytes)
Basic Specification Max. modules installed Up to 12 (available on basic base and added base)
Internal-consumed current (mA) 350mA
Weight (g) 81g

Profibus-DP (Pnet)

XGT Profibus-DP [Pnet] system

Features

  • Profibus-DP protocol
  • Communicates amongst  a master automation device and distributed slave I/O device
  • Fast slave communication without an application layer
  • Transmission speed: 9.6Kbps ~ 12Mbps
  • Transmission distance: Max. 1,200m
  • Max. 126 slave stations available (32 stations per segment)
  • Network setting using N Configurator/XG5000 (Parameter setting, diagnosis and monitoring)
  • I/O data of master station: 7 kbytes
  • Automatic monitoring of slave modules in the network: Auto-scan (XG5000)
  • Multi master
  • Easy configuration tool: N Configurator / XG5000

Specifications

Item XGL-PMEB
Module Type Master
Network Type Profibus-DP
Standard EN50170/DIN19245
Interface RS-485 (Electric)
Transmission Route Bus type
Modulation Type NRZ
MAC Local Token Ring
Max. Distance & Transmission Speed Distance (m) Transmission Speed (bps)
1,200 9.6k/19.2k/31.25k/45.45k/93.7k
1,000 187.5k
400 500k
200 1.5M
100 3M/6M/12M
Max. number of stations per network 126
Max. number of stations per segment 32 (including master & repeater)
Max. number of modules per node 24 modules
Cable used Electric-twist shielded pair cable
Max. communication size 7 KB
Max. size per slave 244 bytes
Max. number of units to be installed XGK-CPUH/XGI-CPUU XGK-CPUS/CPUA/CPUE
12 12
Installation Position XGK-CPUH/XGI-CPUU XGK-CPUS/CPUA/CPUE
Basic base ~ expansion stage 7 Basic base ~ expansion stage 3
Communication Parameters to set XG5000 , SyCon (XGL-PMEA Dedicated Configuration Tool), N Configurator (XGL-PMEB/C Dedicated Configuration Tool)
Internal-consumed current(mA) 500
Weight (g) 88


Item XGL-PSEA
Standard EN50170 / DIN 19245
Interface RS-485 (Electric)
Media access Polling
Topology Bus
Modulation NRZ
Network Interface Auto baud rate
Master / Slave Slave
Max. number of slave per network 99
Max. number of slave per segment 32
Cable Shield twisted pair cable
Max. I/O data 244 byte
Configuration tool XG5000
Transmission
distance
and speed
Trans. speed(kbps) 9.6 19.2 93.75 187.5 500
Max. network length(m) 1200 1200 1200 1000 400
Trans. speed(kbps) 1500 3000 6000 12000 -
Max. network length(m) 200 100 100 100 -
Max num. of node 99(0~98)
Max num. of transmission block 24
Max num. of installation 12ea (XGR: Max. 6ea)
Installation XGK-CPUU/H, XGI-CPUU Main base ~ 7th Expansion base
XGK-CPUE, XGI-CPUE Main base ~ 1st Expansion base
XGK-CPUA/S, XGI-CPUH/S Main base ~ 3rd Expansion base
XGR-CPUH/F, XGR-CPUH/T Main base
Current consumption (mA) 410
Weight (g) 103


Item XGL-PSRA
Standard EN50170 / DIN 19245
Interface RS-485(Electric)
Media access Polling
Topology Bus
Modulation NRZ
Network Interface Auto baud rate
Master / Slave Slave
Max. number of slave per network 100
Max. number of slave per segment 32
Cable Shield twisted pair cable
Max. number of communication points 244 byte
Transmission
distance
and speed
Trans. speed(kbps) 9.6 19.2 93.75 187.5 500
Max. network length(m) 1200 1200 1200 1000 400
Trans. speed(kbps) 1500 3000 6000 12000 -
Max. network length(m) 200 100 100 100 -
Max num. of node 100(0~99)
Max. number of installation 12
Max. digital I/O 768
Max Analog I/O Channel Input : 122ch. / Output : 96ch
Current consumption (mA) 600
Weight (g) 114

XGT Profibus-DP [Pnet] system

Features

  • Profibus-DP protocol
  • Communicates amongst  a master automation device and distributed slave I/O device
  • Fast slave communication without an application layer
  • Transmission speed: 9.6Kbps ~ 12Mbps
  • Transmission distance: Max. 1,200m
  • Max. 126 slave stations available (32 stations per segment)
  • Network setting using N Configurator/XG5000 (Parameter setting, diagnosis and monitoring)
  • I/O data of master station: 7 kbytes
  • Automatic monitoring of slave modules in the network: Auto-scan (XG5000)
  • Multi master
  • Easy configuration tool: N Configurator / XG5000

Specifications

Item XGL-PMEB
Module Type Master
Network Type Profibus-DP
Standard EN50170/DIN19245
Interface RS-485 (Electric)
Transmission Route Bus type
Modulation Type NRZ
MAC Local Token Ring
Max. Distance & Transmission Speed Distance (m) Transmission Speed (bps)
1,200 9.6k/19.2k/31.25k/45.45k/93.7k
1,000 187.5k
400 500k
200 1.5M
100 3M/6M/12M
Max. number of stations per network 126
Max. number of stations per segment 32 (including master & repeater)
Max. number of modules per node 24 modules
Cable used Electric-twist shielded pair cable
Max. communication size 7 KB
Max. size per slave 244 bytes
Max. number of units to be installed XGK-CPUH/XGI-CPUU XGK-CPUS/CPUA/CPUE
12 12
Installation Position XGK-CPUH/XGI-CPUU XGK-CPUS/CPUA/CPUE
Basic base ~ expansion stage 7 Basic base ~ expansion stage 3
Communication Parameters to set XG5000 , SyCon (XGL-PMEA Dedicated Configuration Tool), N Configurator (XGL-PMEB/C Dedicated Configuration Tool)
Internal-consumed current(mA) 500
Weight (g) 88


Item XGL-PSEA
Standard EN50170 / DIN 19245
Interface RS-485 (Electric)
Media access Polling
Topology Bus
Modulation NRZ
Network Interface Auto baud rate
Master / Slave Slave
Max. number of slave per network 99
Max. number of slave per segment 32
Cable Shield twisted pair cable
Max. I/O data 244 byte
Configuration tool XG5000
Transmission
distance
and speed
Trans. speed(kbps) 9.6 19.2 93.75 187.5 500
Max. network length(m) 1200 1200 1200 1000 400
Trans. speed(kbps) 1500 3000 6000 12000 -
Max. network length(m) 200 100 100 100 -
Max num. of node 99(0~98)
Max num. of transmission block 24
Max num. of installation 12ea (XGR: Max. 6ea)
Installation XGK-CPUU/H, XGI-CPUU Main base ~ 7th Expansion base
XGK-CPUE, XGI-CPUE Main base ~ 1st Expansion base
XGK-CPUA/S, XGI-CPUH/S Main base ~ 3rd Expansion base
XGR-CPUH/F, XGR-CPUH/T Main base
Current consumption (mA) 410
Weight (g) 103


Item XGL-PSRA
Standard EN50170 / DIN 19245
Interface RS-485(Electric)
Media access Polling
Topology Bus
Modulation NRZ
Network Interface Auto baud rate
Master / Slave Slave
Max. number of slave per network 100
Max. number of slave per segment 32
Cable Shield twisted pair cable
Max. number of communication points 244 byte
Transmission
distance
and speed
Trans. speed(kbps) 9.6 19.2 93.75 187.5 500
Max. network length(m) 1200 1200 1200 1000 400
Trans. speed(kbps) 1500 3000 6000 12000 -
Max. network length(m) 200 100 100 100 -
Max num. of node 100(0~99)
Max. number of installation 12
Max. digital I/O 768
Max Analog I/O Channel Input : 122ch. / Output : 96ch
Current consumption (mA) 600
Weight (g) 114