Features

3 - Position Enable Switch
3 - Position Enable Switch
Clear Visibility
  • Excellent visibility with high definition and wide screen view
  • 1024 X 600 resolution
  • 16M color
Project Transfer
  • Easy project creation by XP-Builder
  • Convenient downloading/uploading of project files via USB port and ethernet (Multi-language supported)
Project Transfer
3 - Position Enable Switch
3 - Position Enable Switch
Clear Visibility
  • Excellent visibility with high definition and wide screen view
  • 1024 X 600 resolution
  • 16M color
Project Transfer
  • Easy project creation by XP-Builder
  • Convenient downloading/uploading of project files via USB port and ethernet (Multi-language supported)
Project Transfer

Specifications

Model iXP2H-0702D Series iXP2H-0704D Series
Display type TFT color LCD
Screen size 7”
Resolution 1024 x 600 pixels
Color indication 24-bit color (16.7M colors)
Backlight LED method, Automatic On/Off support
Backlight lifetime 50,000 hours
Touch panel Resistive overlay (Pressure type)
Audio Magnetic buzzer (12Ø 85 dB)
Processor ARM Cortex-A9 800 MHz, single core
Memory Flash 8 GB (Small memory: 128 MB)
Operating RAM 1 GB
Backup RAM 1 MB
Backup type Date/time data, logging, alarm, recipe data, non-volatile device
Battery CR1220 (3.0V/210 mAh, Around 3 years/25℃)
Ethernet 1 x 10Base-T/100Base-TX
USB host 1 x USB 2.0 (Below x 1)
RS-232C 1 x RS-232C (Terminal block) -
RS-485 - 1 x RS-485 (Terminal block)
Multiple languages Simultaneous display of 12 languages
Animation GIF format support
Recipe Supported
Data logging Supported
Script launcher Supported
Standard certification CE, KC
Protection standard IP42 (Front)
Dimensions (mm) 195×270×72 (Excluding cables)
Power DC 24 V ±5%
Power consumption (W) 12
Weight (Kg) 1.0 (Excluding cables)
Model iXP2H-0702D Series iXP2H-0704D Series
Display type TFT color LCD
Screen size 7”
Resolution 1024 x 600 pixels
Backlight LED method, Automatic On/Off support

System configuration and features

Front
Front
① TFT-LCD

1024 x 600 TFT LCD, 16.7M color display
Resistive overlay

② Emergency Stop Switch

Immediately stops the control device or turns off the power as a safety feature

③ Left Keypad

Direction key
F1, F2, F3: User defined

④ Right Keypad

User defined
* Generally used as shortcut key of each axis of robot.

⑤ Extension device

Slot of the USB extension device
 • When shipped, it is fastened with a separate cover.
 • When used, the cover can be removed witha Phillips head(+) screwdriver for use.



Device detail
⑥ Reset Switch

Switch for resetting the system

⑦ Debug Port

A debugging port for developers

⑧ USB Host

Connect to USB memory: Backup and send logging, recipe, alarm, and project data.
Connect to user interface: Use the mouse and keyboard.

⑨ USB Device(option)

USB device port(unsupported)

⑩ SD - Card

Software update
SD memory (store data)



Rear
⑪ Enable Switch

Released : Disable
Intermediate : Enable
Fully Pressed : Disable



Junction box
① Ethernet Port

Ethernet : 10Base-T/100Base-TX/1000Base-T
 • Connector for Ethernet connection

② Serial terminal block

RS-485/232C communication connector
 • 0702D(for RS-232 model): Tx, Rx, GND
 • 0704D(for RS-485 model): TRx+, TRx-

③ Switch 2 terminal block

Signal that is controlled from the front side switch of the product.
 • Enable, Emergency(A contact, B contact) switch

④ Switch 1 terminal block

Signal that is controlled from the front side switch of the product.
 • Enable, Emergency(A contact, B contact) switch

⑤ N.C

Not used

⑥ Power terminal block

DC 24 V input terminal block

Front
Front
① TFT-LCD

1024 x 600 TFT LCD, 16.7M color display
Resistive overlay

② Emergency Stop Switch

Immediately stops the control device or turns off the power as a safety feature

③ Left Keypad

Direction key
F1, F2, F3: User defined

④ Right Keypad

User defined
* Generally used as shortcut key of each axis of robot.

⑤ Extension device

Slot of the USB extension device
 • When shipped, it is fastened with a separate cover.
 • When used, the cover can be removed witha Phillips head(+) screwdriver for use.



Device detail
⑥ Reset Switch

Switch for resetting the system

⑦ Debug Port

A debugging port for developers

⑧ USB Host

Connect to USB memory: Backup and send logging, recipe, alarm, and project data.
Connect to user interface: Use the mouse and keyboard.

⑨ USB Device(option)

USB device port(unsupported)

⑩ SD - Card

Software update
SD memory (store data)



Rear
⑪ Enable Switch

Released : Disable
Intermediate : Enable
Fully Pressed : Disable



Junction box
① Ethernet Port

Ethernet : 10Base-T/100Base-TX/1000Base-T
 • Connector for Ethernet connection

② Serial terminal block

RS-485/232C communication connector
 • 0702D(for RS-232 model): Tx, Rx, GND
 • 0704D(for RS-485 model): TRx+, TRx-

③ Switch 2 terminal block

Signal that is controlled from the front side switch of the product.
 • Enable, Emergency(A contact, B contact) switch

④ Switch 1 terminal block

Signal that is controlled from the front side switch of the product.
 • Enable, Emergency(A contact, B contact) switch

⑤ N.C

Not used

⑥ Power terminal block

DC 24 V input terminal block